国产免费一区二区-日韩中文字幕在线视频-欧美色图在线观看-一区二区三区影院-国产伊人网-99精品视频在线播放免费-国产精品毛片一区视频播-亚洲七区-国产精品免费网站-粉嫩av一区二区-成人免费看aa片-国产激情影院-欧美爽爽-亚洲欧美一区二区在线观看-超碰伊人网

產(chǎn)品列表PRODUCTS LIST

聯(lián)系信息

  • 電話:
    189-2580-2250
  • 傳真:
    18925802250
  • 服務(wù)熱線:
    0769-82205353
HES D6601-99A
點(diǎn)擊次數(shù):1467 更新時(shí)間:2019-09-25

HES D6601-99A

本頁(yè)面標(biāo)準(zhǔn)信息均來(lái)源于網(wǎng)絡(luò)收集,或由參與標(biāo)準(zhǔn)制定的供應(yīng)商提供,只作為參考使用,為確保測(cè)試結(jié)果的準(zhǔn)確性、節(jié)省您的時(shí)間,如需HES D6601-99A標(biāo)準(zhǔn)詳細(xì)信息或HES D6601-99A具體測(cè)試方法,請(qǐng)與我們技術(shù)人員聯(lián)系或給我們留言,我們將為您提供相關(guān)的技術(shù)支持。

 

1. SCOPE

This standard specifies accelerated test method for light resistance (*1) of non-metallic materials and products in automobile cabin using light-exposure apparatus with xenon-arc lamp (*2) (hereinafter call “Test apparatus”).

Note:

(*1) The property of resistance to variation of color, gloss, etc. under irradiation of light, and shall be distinguished from weather resistance, which is the property of resistance to variation to natural actions, such as out-door sunlight, wind, rain, etc.

(*2) Test apparatus capable of performing irradiation of an artificial light source closely resembling sunlight for examining part of the properties of light resistance in a short time.

2. DEFINITION OF TERMS

Definitions of main terms used in this standard shall be accordance with Table 1.

Table 1

Term

Definition

1)       Black panel temperature

(hereinafter call “B.P.T”)

The temperature indicated by a black panel thermometer attached to a rack or rotary board, which is representative for the surface temperature of test pieces.

2)       Xenon-arc lamp

An arc lamp which emits by xenon-arc discharge.

3)       Emission part

The part composed of a xenon-arc lamp and a filter.

3.TSET CONDITIONS

For evaluating variation of color, gloss, etc., conditions, such as temperature, humidity, irradiance, etc., which are effective on test results, shall be in accordance with Table 2.

Table 2

Item

Condition

1)       Temperature

B.P.T. 89±3%

2)       Relative humidity

50±5%RH

3)       Irradiance(*3)

48-100W/m2(within 300-400nm)

4)       Irradiance ratio

Irradiance of 320nm max. shall be under 1.5% of that of 300-400nm

5)       Irradiation method

Continuous irradiation

6)       Test period control

According to radiant exposure quantity

Note(*3): Selection of irradiance shall be effective on acceleration, however, irradiance also shall be effective on sample temperature and heat history. Appropriate irradiance is needed to be selected considering effect on sample by temperature.

4. APPARATS AND PERFORMANCE

Test apparatus shall be constructed of an emission part, xenon-arc starting and stabilizing apparatus, irradiance adjusting apparatus, temperature adjust apparatus, test tank, humidity adjusting apparatus, test piece holder, cooling apparatus, instrumentation apparatus, etc.

4.1 Emission Part

4.1.1 Emission Part shall be as follows, according to clause 3:

1) Xenon-arc lamp: Xenon-arc lamps are long arc lamps of a.c. burning in which electrodes are sealed-in both ends of a quartz tube and xenon gas is sealed-in inside, and are used with performing forced water cooling or forced air cooling.

2) Filter: Filters are used for obtaining the required spectral characteristics and for cooling the xenon-arc lamp. For insulating the ultraviolet part, glass filters for ultraviolet-radiation insulation, running water, etc., are used.

3) Other: Based on the portion to be used, material superior in heat resistance, corrosion resistance, humidity resistance, or electric insulation shall be used.

4.1.2 Spectral characteristics of emission part

The xenon-arc lamp shall have a continuous spectrum at least over the wavelength range of 250 to 1200 nm, and shall have a similar spectral characteristics to glass-through-sunlight in combination with filter.

4.1.3 Irradiance of test piece surface

Irradiance of test piece surfaces shall be able to be set on any certain value within 48-100W/m2 at least over the wavelength range of 300 to 400 nm.

Also, spectral irradiances of test piece surfaces in the wavelength of 300 to 400nm shall be indicated for each type of test apparatus. Further, the irradiance in other wavelength ranges or the spectral irradiance at s specific wavelength should also be marked upon agreement between the parties concerned. The measuring method is to be in accordance with the annex of JIS B 7754.

4.1.4 Tolerance in irradiance during operation

It shall be capable of maintaining ±10% of the set irradiance.

4.1.5 Tolerance in irradiance of test pieces surfaces

The difference of irradiances of test piece surfaces due to the position must not exceed 10% of the maximum value.

4.1.6 Irradiation method

As a rule, a certain constant irradiance shall be kept continuously during operation.

4.2 Irradiance Adjusting Apparatus

The irradiance adjusting apparatus is an apparatus to correct the attenuation of radiation energy accompanying the use of a xenon-arc lamp and filter, measuring the irradiance in the wavelength of 300 to 400 nm, and shall be provided with one of the following conditions:

1) It shall be capable of manual adjustment of the lamp power to make the irradiance constant.

2) It shall be capable of automatic control of the lamp power to make the irradiance constant.

3) It shall be capable of manual adjustment of the lamp power stepwise accoding to the time of use.

4.3Black Panel Thermometer

Black panel thermometer is so structured that the heat sensitive body, bimetal, platinum resistor, thermistor, thermoelectric couple, etc., is attached coincident with the center of the metal plate and is adhered tightly to the heat sensitive body protecting tube.

Remarks: Structures and dimensions shall be in accordance with 5.7(2) and Attached Fig.1. Type A of JIS B 7754.

4.4 Test Tank

Temperature and humidity in test tank shall be as follows:

1) B.P.T. at the position of test piece shall be 89±3℃.

Remarks: Temperature will be different depending on the combination of xenon-arc lamp type and filter.

2) Relative humidity

It shall favorably be capable of keeping relative humidity 50±5% under the temperature specified in 1). Further, relative humidity shall be measured at the point close to and inside the exit of test tank.

4.5 Other

Items unspecified in the foregoing clauses, such as test tank, xenon-arc starting and stabilizing apparatus, temperature adjusting apparatus, humidity adjusting apparatus, test piece holder, cooling apparatus, instrumentation apparatus, etc., shall be in accordance with JIB B 7754.

5. TEST PIECE

5.1Dimensions of Test Piece

Irradiation area of test piece shall be 30 mm min in vertical direction and over 30mm min horizontal direction, and thickness shall be determined according to agreement to agreement between the parties concerned. Further, when test piece has urethane foam backing layer as part construction, density and composition, etc. of the layer shall be determined between the parties concerned.

5.2 Other

In case of test piece with texture direction, such as fabrics, etc., attachment direction relative to test apparatus shall be indicated.

6. PROCEDRE

6.1 Attach test piece on test piece holder firmly so that it won’t drop. Further, when backing material like urethane foam is attached on backside of test piece, the backside shall be contracted with backing material as tightly as possible so that it shall not become loose.

6.2Set test piece holders with test pieces attached on a rack or a rotary board without gaps between the holders. When there are some test piece holders without test pieces, put white-colored papers, aluminum plates, stainless steel plates, etc., on all of the holder in order to keep heat equilibrium inside test tank.

6.3 Select a certain irradiance within 48-100W/m2 in the wavelength of 300-400nm, and adjust test apparatus so that the selected irradiance shall be kept constant during exposure.

6.4 Adjust B.P.T during exposure within 89±3℃ by temperature adjusting apparatus.

6.5 Adjust humidity during exposure within 50±5% RH.

6.6 In case of broad samples, their position shall favorably be replaced at certain intervals for better test accuracy.

Remarks: Radiant exposure quantity can be calculated by the following formula:

Radiant exposure quantity (KJ/m2) = Irradiance (W/m2)×Time(Hr)×3.6

Applicable standards

JIS B 7754

JASO M 346

Reference Standard

 

<

Applicable Standard

 

<

 

上一篇:HG/T 2006-2006

下一篇:GMW14872-2013

返回列表>>
聯(lián)系人
在線客服
用心服務(wù) 成就你我

粵公網(wǎng)安備44190002001386號(hào)

主站蜘蛛池模板: 欧美视频免费看 | 成人免费看片网站 | 欧美图片自拍偷拍 | 国产黄色录像片 | 极品福利视频 | 日本一区二区视频免费 | yy6080久久| 国产91在线播放精品91 | av手机在线看 | 亚洲图片88 | 国产精品91久久 | 涩涩涩在线视频 | 99国产精品一区二区三区 | 成人免费视频网址 | 最新在线视频 | 夜噜噜| 国产成人在线视频播放 | 午夜寂寞福利 | 黄色大片儿 | 好吊色一区二区三区 | 亚洲精品18在线观看 | 日日噜噜噜噜人人爽亚洲精品 | 国产特级淫片免费看 | 男女久久久| 蜜臀久久99精品久久久久宅男 | 小镇姑娘国语版在线观看免费 | 亚洲电影中文字幕 | 特黄特黄视频 | 久久精品国产精品亚洲毛片 | 蜜桃视频污 | 妺妺窝人体色777777 | 亚洲美女视频一区 | 99免费精品视频 | 欧洲成人精品 | 国产精品区在线观看 | 在线观看小视频 | 亚洲精品在线免费观看视频 | 日本人妻一区二区三区 | 日韩一区二区在线观看 | 国产欧美大片 | 日韩久久精品视频 | 香蕉视频黄污 | 色老头一区二区三区 | 欧美激情亚洲色图 | 日韩精品中文字幕一区 | 妖精视频在线观看免费 | 日韩xxx视频 | 亚洲人午夜射精精品日韩 | 中文字幕免费av | 午夜精品视频在线 | 午夜精品区 | 六月婷婷七月丁香 | 欧美高清免费 | 亚洲乱色| 日韩av在线一区二区三区 | 欧美精产国品一二三区 | 91免费看国产 | 色偷偷av一区二区三区 | 成人福利一区二区三区 | 国产美女操 | 1000部啪啪未满十八勿入超污 | 欧美国产中文字幕 | 中文字幕观看在线 | 色片免费看 | 国产a级黄色 | 摸大乳喷奶水www视频 | av制服丝袜| 羽月希奶水一区二区三区 | 亚洲精品在线一区二区 | 欧美二三区 | 亚洲午夜在线 | 国模少妇一区二区三区 | 午夜激情婷婷 | 在线观看福利片 | av在线亚洲天堂 | 最新99热| 黄色天天影视 | 看免费的毛片 | 91精品国产综合久久久久久久 | 成人av软件| free性欧美hd精品4k | 国产精品日韩一区二区 | 日本学生初尝黑人巨免费视频 | 91狠狠爱| 亚洲一区二区三区四区电影 | 男人天堂手机在线 | 99精品国自产在线 | 日韩精品一区二区三区免费视频 | 粗喘呻吟撞击猛烈疯狂 | 欧美黄色一区二区 | 久久久久亚洲av成人片 | 乱短篇艳辣500篇h文最新章节 | 国产成人无码一区二区在线观看 | 朋友的姐姐2在线观看 | 99re热这里只有精品视频 | 国产无遮掩| www.男人天堂.com | 天堂资源在线播放 | 人人夜 |